How air-conditioner size is estimated
An air conditioner's capacity is the amount of heat it can remove per hour, measured in BTU per hour (British thermal units) in North America and in kilowatts elsewhere. One refrigeration ton is 12,000 BTU/h, about 3.52 kW.
For a single room, the ENERGY STAR program publishes a simple sizing chart based on floor area, assuming 8 ft ceilings. It works out to roughly 20 BTU/h per square foot for small rooms, falling to about 16 BTU/h per square foot for large open spaces. ENERGY STAR then recommends these adjustments:
- heavily shaded room: reduce 10%
- very sunny room: increase 10%
- more than two people regularly in the room: add 600 BTU/h per extra person
- kitchen: add 4,000 BTU/h
This calculator also scales the result for ceiling height (relative to 8 ft) and offers a ±10% climate factor. Both are rules of thumb rather than part of the official chart.
BTU, kW, tons and 匹
The units convert as follows:
1 kW = 3,412 BTU/h, 1 ton = 12,000 BTU/h = 3.517 kW
In China air conditioners are sold by 匹 (pǐ, "horsepower"). The name comes from the compressor's input power, but in practice it is used as a capacity class: a 1 匹 unit cools about 2,300–2,600 W, 1.5 匹 about 3,500 W, 2 匹 about 5,000 W and 3 匹 about 7,200 W. The calculator uses 1 匹 ≈ 2,500 W of cooling, which is close to 8,500 BTU/h.
| Size | Cooling (W) | BTU/h |
|---|---|---|
| 1 匹 | ≈ 2,500 | ≈ 8,500 |
| 1.5 匹 | ≈ 3,500 | ≈ 12,000 |
| 2 匹 | ≈ 5,000 | ≈ 17,000 |
| 3 匹 | ≈ 7,200 | ≈ 24,500 |
Worked example
A 300 ft² bedroom (about 28 m²) with 8 ft ceilings, average sun, two occupants and a moderate climate:
- Chart: 300 ft² falls in the 250–300 ft² row → 7,000 BTU/h.
- Adjustments: ceiling 8 ÷ 8 = 1, sun × 1, climate × 1, no extra people, not a kitchen.
- Result: 7,000 BTU/h = 2.05 kW = 0.58 tons, so a 7,000 or 8,000 BTU/h window unit fits.
If the same room is very sunny and used by four people, the estimate becomes 7,000 × 1.1 + 2 × 600 = 8,900 BTU/h, so step up to a 9,000 or 10,000 BTU/h unit.
Getting the size right
- Bigger is not better. An oversized unit reaches the thermostat setting quickly, shuts off and never runs long enough to dehumidify, leaving the room cold and clammy.
- Undersized units run constantly on hot days and may never reach the set temperature.
- Rooms under a hot roof, with large west-facing windows, or open to other rooms need more capacity than the chart suggests.
- For heating, the calculator uses 30–60 BTU/h per ft² depending on climate — a rough guide for a space heater or mini-split. Whole-house systems should be sized with an ACCA Manual J load calculation by an HVAC professional.
Frequently asked questions
How many BTU do I need for a 12 × 12 room?
A 12 × 12 ft room is 144 ft², which the ENERGY STAR chart puts at 5,000 BTU/h. Add 10% if it is very sunny, and 600 BTU/h for each regular occupant beyond two.
How many square feet does 12,000 BTU cool?
On the ENERGY STAR chart, 12,000 BTU/h (1 ton) covers about 450–550 ft². In hot, sunny rooms the practical area is smaller.
What does 匹 mean on Chinese air conditioners?
匹 (pǐ) literally means horsepower and once described compressor input power. Today it is a capacity class: 1 匹 is roughly 2,500 W (about 8,500 BTU/h) of cooling, 1.5 匹 about 3,500 W and 2 匹 about 5,000 W.
Why does the Chinese method give a bigger result than the US chart?
The W/m² rules used in China assume hotter, more humid summers, less insulation, high occupancy and often heating as well. The ENERGY STAR chart assumes a typical insulated US room. Use the method that matches your building and climate.
How do I convert BTU to kW?
Multiply BTU/h by 0.000293 (or divide by 3,412). For example 12,000 BTU/h × 0.000293 = 3.52 kW.